• POLE QUANTITY : 1
  • MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE : 20.0 AMPERES DC SINGLE LOCATION
  • OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS : 28.0 DC SINGLE LOCATION
  • MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS : 575.0 DC SINGLE LOCATION​​​​​​​
  • CIRCUIT PROTECTION TYPE : OVERCURRENT SINGLE LOCATION​​​​​​​
  • TRIP RELEASE METHOD : THERMAL SINGLE LOCATION​​​​​​​
  • INTERNAL TRIP RELEASE CONFIGURATION : SERIES TRIP SINGLE LOCATION​​​​​​​
  • TRIP RELEASE AMBIENT TEMP RATING : 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION​​​​​​​
  • TRIP RELEASE CHARACTERISTIC : TIME DELAY SINGLE LOCATION
  • TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT : 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
  • ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT : 138.0 SINGLE LOCATION​​​​​​​
  • RESET METHOD : AUTOMATIC
  • BODY STYLE : 16A SINGLE POLE TYPE​​​​​​​
  • BODY LENGTH : 2.000 INCHES NOMINAL​​​​​​​
  • BODY WIDTH : 1.813 INCHES NOMINAL
  • BODY HEIGHT : 1.875 INCHES MAXIMUM​​​​​​​ 
  • CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH : 0.625 INCHES NOMINAL​​​​​​​
  • DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH : 
    1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM​​​​​​​
  • CASE MATERIAL : PLASTIC​​​​​​​
  • MOUNTING FACILITY TYPE AND QUANTITY : 2 UNTHREADED HOLE​​​​​​​
  • UNTHREADED MOUNTING HOLE DIAMETER : 0.174 INCHES NOMINAL​​​​​​​
  • TERMINAL TYPE AND QUANTITY : 2 QUICK DISCONNECT, MALE​​​​​​​
  • INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED : WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT​​​​​​​
  • III STORAGE TYPE : GENERAL PURPOSE WAREHOUSE​​​​​​​
  • III FRAGILITY FACTOR : MODERATELY RUGGED​​​​​​​
  • MANUFACTURERS CODE : 58536​​​​​​​
  • NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE : AA55571​​​​​​​
  • MANUFACTURERS CODE : 58536
  • DEFINITIVE GOVERNMENT SPEC/STD REFERENCE : AA55571/01-002​​​​​​​

Circuit Breaker

  • Thermal circuit breaker. 20 amps. Very rugged for harsh conditions. Ignition & splash protected. Automatic reset, sealed construction, molded-in & rubber covered terminals. Used in many military jeeps and military vehicles.